Skip banner and navigation tools .
Home > GRB products > Burst Analyser > GRB 160314A
GRB 160314A
The Swift Burst Analyser — GRB 160314A
Last updated using ObsID 00679120000, version 5;
Data were analysed using HEASOFT version 6.32
Related pages:
Enhanced position
| Light curve
| Spectrum
| Image
| XRT Catalogue entry
| Download obs data
| BAT analysis
| GCN Notices
| GCN Circulars
From 2016 January, the light curve plots support interactive zooming and exploring. See the jsPlot
documentation for details.
Also, from the same date, the first plot on this page is the observed flux
in the native band of each instrument (including UVOT where available).
Index of bursts .
About these products .
Caveats
If the answer to any of the following is "yes," you should investigate further before
accepting the light curves. See the documentation for details.
Is Γ discontinuous between BAT and XRT?
Is the BAT spectral fit a cut-off power law?
Are the Γ values extreme?
Are the errors on Γ/CF large?
Do all the BAT or XRT bins have identically Γ/CF bins?
Close .
Jump to:
Observed flux | BAT+XRT | BAT | XRT | BAT no evolution .
Downloads:
BAT spectral evolution data | XRT spectral evolution data | All files for this object: [tar ][tar.gz ][zip ].
All data uses absorption NH =0.062 × 1022 cm-2 at z=0 and 0.04 × 1022 cm-2 at z=0.726. (Source: the late-time spectrum from the XRT spectrum repository ).
Observed BAT+XRT+UVOT flux
Reliability checks .
Show Observed Flux hardness ratio .
BAT binning:
SNR 4 SNR 5 SNR 6 SNR 7 4 ms bins 64 ms bins 1 s bins 10 s bins
Subplot:
no photon index counts to flux conversion factor
Show UVOT upper limits?
Renormalise UVOT data?
Show 'bad' BAT points? Explain
■ BAT
■ XRT (all modes)
■ white
■ v
■ b
■ u
■ uvw1
■ uvw2
■ uvm2
BAT-XRT unabsorbed flux light curves
Reliability checks .
Show BAT-XRT hardness ratio .
BAT binning:
SNR 4 SNR 5 SNR 6 SNR 7 4 ms bins 64 ms bins 1 s bins 10 s bins
Subplot:
no photon index counts to flux conversion factor
Display which bands?
Flux density at 10 keV
0.3—10 keV flux
15—50 keV flux
Show 'bad' BAT points? Explain
BAT unabsorbed flux light curves
Reliability checks .
Show BAT hardness ratio .
BAT binning:
SNR 4 SNR 5 SNR 6 SNR 7 4 ms bins 64 ms bins 1 s bins 10 s bins
Subplot:
no photon index counts to flux conversion factor
Display which bands?
Flux density at 10 keV
0.3—10 keV flux
15—50 keV flux
Show 'bad' BAT points? Explain
XRT unabsorbed flux light curves
Reliability checks .
Show XRT hardness ratio .
Subplot:
no photon index counts to flux conversion factor
Display which bands?
Flux density at 10 keV
0.3—10 keV flux
15—50 keV flux
The fit to the T90 spectrum was used to create the plots in this section. T90 was 8.7, from 0.2 to 8.9 The spectral fit used was a power-law with photon index: 1.45
Count-rate light curves are available from GCN .
BAT unabsorbed flux light curves, no spectral evolution
BAT binning:
SNR 4 SNR 5 SNR 6 SNR 7 4 ms bins 64 ms bins 1 s bins 10 s bins
Display which bands?
Flux density at 10 keV
0.3—10 keV flux
15—50 keV flux
Show 'bad' BAT points? Explain