Skip banner and navigation tools.

 |  site map

Einstein Probe trigger EP250827a
Source 10 (SWIFT J001255.3-563228)

Image of the XRT detection

This source is detected in 1 block. Show all images.

Image of the LC

Spectrum

Image of the spectrum
Source details
Rank/Classification: 3: Uncatalogued X-ray source
RA (J2000):00h 12m 55.31s (= 3.23047°)
Dec (J2000):-56° 32′ 28.0″ (= -56.5411°)
Error (radius, 90%):7.4″
Detection flag:Good
XRT exposure:10.0 ks (vignetting corrected)
Peak rate:1.5 (+0.6, -0.5) ×10-3 ct s-1
Peak flux:6.3 (+2.7, -2.2) ×10-14 erg cm-2 s-1
Mean rate:1.5 (+0.6, -0.5) ×10-3 ct s-1
Mean flux:6.3 (+2.7, -2.2) ×10-14 erg cm-2 s-1
Has spectral fit?Yes
NH 1.46 × 1020 cm-2
Γ 1.86
Database ID:451
Things to check:
Optical Loading: No warning (automatic)
Stray Light: No warning (automatic)
Extended Emission: No warning (automatic)
Catalogue information
Known X-ray emitter?No. Get XMM upper limit
Rass upper limit20.14 ct s-1
Obs rate/Rass UL≤0 σ
Fading? ≤3-σ signifance.
Near 2MASS source? Yes, 1 match. Show details.
Near SIMBAD source?No.
High proper motion star?No.
Catalogue SearchCone search radius 22″ Vizier | Simbad | NED | X-ray master | LSXPS | 3XMM-DR5

Notes
All XRT count rates and fluxes are 0.3—10 keV
1Catalogued count-rates have been converted to XRT equivalents.
2Catalogued upper limits and fluxes have been converted to the XRT equivalent using the automatic power-law spectral fit described above.

2MASS objects near the source

ID Position Offset from
XRT source
J H K