                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Mon 15 Dec 20:20:49 GMT 2025
             Host Name: xep-swiftv-p3.star.le.ac.uk
   Current Working Dir: /scratch/batxrtlc_vZ7J7
======================================================================

  Trigger: 01423875      Segment: 000

  BAT Trigger Time: 787395774.4   [s; MET]
      Trigger Stop: 787395774.656   [s; MET]
               UTC: 2025-12-14T09:02:17.541060    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 330.216936794547   Dec: -9.16703482485966  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    8.62
     Image Trigger?:     NO
     Rate S/N Ratio:     22.0227155455452  [ if not an image trigger ]
     Image S/N Ratio:    8.62

  Analysis Position:   [ source = BAT ]
    RA: 330.216936794547   Dec: -9.16703482485966  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 330.222106635729   Dec: -9.1507422360164  [deg; J2000]  
        { 22h 00m 53.3s , -09d 09' 02.7" }
         +/- 1.14342423553149 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.391197759006801 [arcmin] (formal 1-sigma fit error)
    SNR: 25.1168378159412



  Partial Coding Fraction: 0.9921875    [ including projection effects ]

  Duration
     T90: 9.60799992084503 +/- 0.691167139041994
        Measured from: 0.00400006771087646
                   to: 9.61199998855591     [s; relative to TRIGTIME]
     T50: 4.76799988746643 +/- 0.641760119077162
        Measured from: 0.720000028610229
                   to: 5.48799991607666     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: -0.131999969482422     
                   to: 0.868000030517578     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -0.192000031471252     
                   to: 10.4079999923706     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.327127   0.380828   0.215374   0.037823
           0.020695   0.021701   0.018062   0.013807 [error]
 Peak      0.067959   0.103907   0.082176   0.016215
           0.006855   0.007944   0.006774   0.004619 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================