                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Tue Nov 11 14:50:36 GMT 2025
             Host Name: fireball.star.le.ac.uk
   Current Working Dir: /fbdata/autoproc/tmp/batxrtlc_eWOxk
======================================================================

  Trigger: 01114937      Segment: 000

  BAT Trigger Time: 678816583.744   [s; MET]
      Trigger Stop: 678816585.792   [s; MET]
               UTC: 2022-07-06T16:09:14.296300    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 0.586794992558329   Dec: -16.3913692713963  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    8.84
     Image Trigger?:     NO
     Rate S/N Ratio:     11.6189500386223  [ if not an image trigger ]
     Image S/N Ratio:    8.84

  Analysis Position:   [ source = BAT ]
    RA: 0.586794992558329   Dec: -16.3913692713963  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 0.574964027381256   Dec: -16.4074776789611  [deg; J2000]  
        { 00h 02m 18.0s , -16d 24' 26.9" }
         +/- 1.82916637678964 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.655196200560827 [arcmin] (formal 1-sigma fit error)
    SNR: 12.8372186251725



  Partial Coding Fraction: 0.734375    [ including projection effects ]

  Duration
     T90: 76.2159999608994 +/- 18.3648447906867
        Measured from: -55.3240000009537
                   to: 20.8919999599457     [s; relative to TRIGTIME]
     T50: 24.1719999313354 +/- 10.4059336158538
        Measured from: -11.8999999761581
                   to: 12.2719999551773     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 0.0920000076293945     
                   to: 1.09200000762939     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -71.039999961853     
                   to: 36.0360000133514     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.765903   0.924736   0.540129   0.232923
           0.067574   0.069787   0.062236   0.058325 [error]
 Peak      0.031975   0.052512   0.026280   0.008894
           0.007350   0.007517   0.006626   0.005685 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================