                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Tue Nov 11 13:39:45 GMT 2025
             Host Name: fireball.star.le.ac.uk
   Current Working Dir: /fbdata/autoproc/tmp/batxrtlc_L1wFl
======================================================================

  Trigger: 00706871      Segment: 000

  BAT Trigger Time: 491736527.168   [s; MET]
      Trigger Stop: 491736528.192   [s; MET]
               UTC: 2016-08-01T09:28:30.522860    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 212.762767149869   Dec: 13.4995972351227  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    9.93
     Image Trigger?:     NO
     Rate S/N Ratio:     14.9666295470958  [ if not an image trigger ]
     Image S/N Ratio:    9.93

  Analysis Position:   [ source = BAT ]
    RA: 212.762767149869   Dec: 13.4995972351227  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 212.769892923774   Dec: 13.4842127597301  [deg; J2000]  
        { 14h 11m 04.8s , +13d 29' 03.2" }
         +/- 1.77900347820313 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.848836062296315 [arcmin] (formal 1-sigma fit error)
    SNR: 13.3574314916609



  Partial Coding Fraction: 0.734375    [ including projection effects ]

  Duration
     T90: 2.88799995183945 +/- 0.45171675569351
        Measured from: -1.21200001239777
                   to: 1.67599993944168     [s; relative to TRIGTIME]
     T50: 1.38399994373322 +/- 0.43947689834785
        Measured from: -0.455999970436096
                   to: 0.927999973297119     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: -0.0239999890327454     
                   to: 0.976000010967255     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -1.3759999871254     
                   to: 1.81200003623962     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.110901   0.117896   0.070131   0.018410
           0.013183   0.013557   0.011462   0.009096 [error]
 Peak      0.048004   0.063271   0.022944  -0.000096
           0.007497   0.007882   0.006224   0.004788 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================