                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Tue Nov 11 13:17:01 GMT 2025
             Host Name: fireball.star.le.ac.uk
   Current Working Dir: /fbdata/autoproc/tmp/batxrtlc_SHHrQ
======================================================================

  Trigger: 00623158      Segment: 000

  BAT Trigger Time: 441786546.692   [s; MET]
      Trigger Stop: 441786546.756   [s; MET]
               UTC: 2015-01-01T06:28:53.699400    [includes UTCF correction] 
       Where From?: (*SHORT BURST*) TDRSS scaled map message

  BAT 
    RA: 312.631006525829   Dec: 36.727689408524  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    7.46
     Image Trigger?:     NO
     Rate S/N Ratio:     19.4422220952236  [ if not an image trigger ]
     Image S/N Ratio:    7.46

  Analysis Position:   [ source = BAT ]
    RA: 312.631006525829   Dec: 36.727689408524  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 312.60160040026   Dec: 36.6646971446102  [deg; J2000]  
        { 20h 50m 24.4s , +36d 39' 52.9" }
         +/- 2.51604331386462 [arcmin] (estimated 90% radius based on SNR)
         +/- 1.60873042720674 [arcmin] (formal 1-sigma fit error)
    SNR: 8.14074090121552



  Partial Coding Fraction: 0.9140625    [ including projection effects ]

  Duration
     T90: 0.0480000376701355 +/- 0.0357770801763245
        Measured from: 0.00400000810623169
                   to: 0.0520000457763672     [s; relative to TRIGTIME]
     T50: 0.0320000052452087 +/- 0.0160000324249268
        Measured from: 0.0200000405311584
                   to: 0.0520000457763672     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: -0.455999970436096     
                   to: 0.544000029563904     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 0.00400000810623169     
                   to: 0.0680000185966492     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.008137   0.015949   0.012383   0.000846
           0.002251   0.002618   0.002686   0.002002 [error]
 Peak     -0.001384   0.024794   0.012158   0.008911
           0.006919   0.006998   0.006067   0.005429 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================