                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Tue Nov 11 12:49:18 GMT 2025
             Host Name: fireball.star.le.ac.uk
   Current Working Dir: /fbdata/autoproc/tmp/batxrtlc_bD9wO
======================================================================

  Trigger: 00547420      Segment: 000

  BAT Trigger Time: 381352219.072   [s; MET]
      Trigger Stop: 381352221.12   [s; MET]
               UTC: 2013-01-31T19:10:08.907360    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 173.951574019347   Dec: 15.0356350571936  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    7.85
     Image Trigger?:     NO
     Rate S/N Ratio:     16.7332005306815  [ if not an image trigger ]
     Image S/N Ratio:    7.85

  Analysis Position:   [ source = BAT ]
    RA: 173.951574019347   Dec: 15.0356350571936  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 173.959899695505   Dec: 15.0310809115505  [deg; J2000]  
        { 11h 35m 50.4s , +15d 01' 51.9" }
         +/- 1.71678426332777 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.79144096092231 [arcmin] (formal 1-sigma fit error)
    SNR: 14.0543318293421



  Partial Coding Fraction: 0.515625    [ including projection effects ]

  Duration
     T90: 4.31199991703033 +/- 0.271204756814321
        Measured from: -0.0680000185966492
                   to: 4.24399989843369     [s; relative to TRIGTIME]
     T50: 2.82799994945526 +/- 0.767189668963876
        Measured from: 0.687999963760376
                   to: 3.51599991321564     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: -0.280000030994415     
                   to: 0.719999969005585     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -0.280000030994415     
                   to: 4.40399998426437     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.105976   0.147036   0.161318   0.056462
           0.016609   0.017735   0.016388   0.014874 [error]
 Peak      0.033720   0.037202   0.038620   0.016004
           0.007667   0.008145   0.007719   0.007139 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================