                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Tue Nov 11 12:45:53 GMT 2025
             Host Name: fireball.star.le.ac.uk
   Current Working Dir: /fbdata/autoproc/tmp/batxrtlc_twIEH
======================================================================

  Trigger: 00535764      Segment: 000

  BAT Trigger Time: 371646940.16   [s; MET]
      Trigger Stop: 371646942.208   [s; MET]
               UTC: 2012-10-11T11:15:30.412760    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 260.200124470458   Dec: 41.1367639177282  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    7.18
     Image Trigger?:     NO
     Rate S/N Ratio:     13.1529464379659  [ if not an image trigger ]
     Image S/N Ratio:    7.18

  Analysis Position:   [ source = BAT ]
    RA: 260.200124470458   Dec: 41.1367639177282  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 260.201653511306   Dec: 41.120438368065  [deg; J2000]  
        { 17h 20m 48.4s , +41d 07' 13.6" }
         +/- 1.6917588184112 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.642287994364191 [arcmin] (formal 1-sigma fit error)
    SNR: 14.3522699963961



  Partial Coding Fraction: 0.328125    [ including projection effects ]

  Duration
     T90: 77.4319999217987 +/- 12.8499240376996
        Measured from: -4.94400000572205
                   to: 72.4879999160767     [s; relative to TRIGTIME]
     T50: 25.0799999833107 +/- 9.9016379952433
        Measured from: 1.09199994802475
                   to: 26.1719999313354     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 0.631999969482422     
                   to: 1.63199996948242     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -7.45200002193451     
                   to: 81.811999976635     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.428814   1.106190   1.048735   0.260196
           0.090978   0.087086   0.076617   0.064850 [error]
 Peak      0.029229   0.051845   0.058975   0.020480
           0.012756   0.012229   0.011339   0.009707 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================