                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Tue Nov 11 12:26:42 GMT 2025
             Host Name: fireball.star.le.ac.uk
   Current Working Dir: /fbdata/autoproc/tmp/batxrtlc_hTx3z
======================================================================

  Trigger: 00444912      Segment: 000

  BAT Trigger Time: 318770246.656   [s; MET]
      Trigger Stop: 318770246.72   [s; MET]
               UTC: 2011-02-07T11:17:20.015680    [includes UTCF correction] 
       Where From?: (*SHORT BURST*) TDRSS scaled map message

  BAT 
    RA: 12.5424372427686   Dec: -10.8057018983402  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    7.39
     Image Trigger?:     NO
     Rate S/N Ratio:     15.5884572681199  [ if not an image trigger ]
     Image S/N Ratio:    7.39

  Analysis Position:   [ source = BAT ]
    RA: 12.5424372427686   Dec: -10.8057018983402  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 12.5450635806144   Dec: -10.7961241278935  [deg; J2000]  
        { 00h 50m 10.8s , -10d 47' 46.0" }
         +/- 1.22537168219928 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.404613270901694 [arcmin] (formal 1-sigma fit error)
    SNR: 22.7520988570425



  Partial Coding Fraction: 1    [ including projection effects ]

  Duration
     T90: 82.9159999489784 +/- 10.4995437823175
        Measured from: 0.339999973773956
                   to: 83.2559999227524     [s; relative to TRIGTIME]
     T50: 29.9679999351501 +/- 8.23631108270928
        Measured from: 16.8959999680519
                   to: 46.8639999032021     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: -0.110000014305115     
                   to: 0.889999985694885     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -0.0879999995231628     
                   to: 95.7919999957085     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.630857   0.910074   0.651539   0.154272
           0.047665   0.048876   0.046377   0.046872 [error]
 Peak      0.039227   0.051114   0.040188   0.026918
           0.005297   0.005708   0.005597   0.005325 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================