                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Tue Nov 11 11:28:34 GMT 2025
             Host Name: fireball.star.le.ac.uk
   Current Working Dir: /fbdata/autoproc/tmp/batxrtlc_KrthH
======================================================================

  Trigger: 00207399      Segment: 000

  BAT Trigger Time: 167907280   [s; MET]
      Trigger Stop: 167907408   [s; MET]
               UTC: 2006-04-28T08:54:38.839960    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 235.350233277521   Dec: 62.0100932089346  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    14.21
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    14.21

  Analysis Position:   [ source = BAT ]
    RA: 235.350233277521   Dec: 62.0100932089346  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 235.34517233621   Dec: 62.0227811827729  [deg; J2000]  
        { 15h 41m 22.8s , +62d 01' 22.0" }
         +/- 2.78142813213284 [arcmin] (estimated 90% radius based on SNR)
         +/- 1.68221634587361 [arcmin] (formal 1-sigma fit error)
    SNR: 7.05423678027448



  Partial Coding Fraction: 0.7421875    [ including projection effects ]

  Duration
     T90: 96 +/- 50.5964425626941
        Measured from: -15
                   to: 81     [s; relative to TRIGTIME]
     T50: 16 +/- 22.6274169979695
        Measured from: 1
                   to: 17     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 8.5     
                   to: 9.5     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -15     
                   to: 113     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.957330   0.759134   0.077942   0.046403
           0.063941   0.065330   0.057626   0.050898 [error]
 Peak      0.019331   0.016583   0.003086  -0.005080
           0.005829   0.005909   0.005156   0.004385 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================