                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Tue Nov 11 11:25:48 GMT 2025
             Host Name: fireball.star.le.ac.uk
   Current Working Dir: /fbdata/autoproc/tmp/batxrtlc_WOf8I
======================================================================

  Trigger: 00176918      Segment: 000

  BAT Trigger Time: 158703344.192   [s; MET]
      Trigger Stop: 158703345.216   [s; MET]
               UTC: 2006-01-11T20:15:43.242160    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 286.33719257667   Dec: 70.3598868857769  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    6.97
     Image Trigger?:     NO
     Rate S/N Ratio:     18.5202591774521  [ if not an image trigger ]
     Image S/N Ratio:    6.97

  Analysis Position:   [ source = BAT ]
    RA: 286.33719257667   Dec: 70.3598868857769  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 286.438238781477   Dec: 70.3795861065374  [deg; J2000]  
        { 19h 05m 45.2s , +70d 22' 46.5" }
         +/- 1.49655465780438 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.694533479653339 [arcmin] (formal 1-sigma fit error)
    SNR: 17.099606586631



  Partial Coding Fraction: 0.2851562    [ including projection effects ]

  Duration
     T90: 58.8320000171661 +/- 4.29058130905367
        Measured from: -1.2039999961853
                   to: 57.6280000209808     [s; relative to TRIGTIME]
     T50: 21.1440000236034 +/- 3.49172738252821
        Measured from: 2.28799998760223
                   to: 23.4320000112057     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 0.363999992609024     
                   to: 1.36399999260902     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -2.02799999713898     
                   to: 61.6960000097752     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.509756   0.584680   0.837773   0.341266
           0.062464   0.064524   0.057378   0.047598 [error]
 Peak      0.047206   0.029804   0.095829   0.016735
           0.009980   0.011211   0.010589   0.007989 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================